Dose
From particle spectra to what a person or a chip absorbs, and how the "dose here" panel puts that next to doses you already know.
Three quantities
- Absorbed dose is energy deposited per unit mass, in gray (Gy). In silicon it is often given in rad: 1 Gy = 100 rad.
- Dose equivalent, in sievert (Sv), weights absorbed dose by how damaging the radiation is to tissue. A slow heavy nucleus does far more harm per gray than a gamma ray. The weight is the quality factor Q, which depends on how densely the particle deposits energy.
- Total ionizing dose in silicon is what degrades electronics over a mission.
How we compute dose
- Method
- Charged-particle fluence times stopping power, with the ICRP 60 quality factor; neutrons and photons as the mean dose in a water sphere of 15 cm radius.
- Checked against
- MSL/RAD in cruise and the DOSIS dosimeters on the ISS.
- Expect
- A factor 2 to 3. The mean quality factor is low because target fragments made inside the body are left out.
Starting from the spectra inside a wall (see shielding):
- Charged particles give a point dose: fluence times stopping power, integrated over energy. Proton stopping powers come from Geant4. Heavier nuclei use the proton value scaled by the Barkas effective charge Barkas (1963). Electrons and positrons use the collision stopping power of ICRU Report 37 ICRU Report 37 (1984) Sternheimer et al. (1984).
- The quality factor is Q(L) from ICRP Publication 60 ICRP Publication 60 (1991), evaluated at each particle's energy loss rate in water.
- Neutrons and photons deposit energy through the particles they set in motion, which needs a volume. We use the mean dose in a water sphere of 15 cm radius per unit fluence, computed with Geant4.
The charged and neutral parts therefore answer slightly different questions, a point and a body-sized sphere. Both are reported.
The "dose here" panel
Click empty space in the 3D explorer and the panel shows four targets.
| Target | What it stands for |
|---|---|
| Astronaut on a spacewalk | Dose equivalent at 5 g/cm² depth, the depth of blood-forming organs, behind a 0.3 g/cm² suit |
| Astronaut inside | The same, behind the wall you choose: 1, 3, 10 or 30 g/cm² |
| Silicon chip, exposed | Absorbed dose in silicon behind a 0.3 g/cm² lid |
| Silicon chip inside | Absorbed dose in silicon behind the chosen wall |
Thicknesses between the five simulated ones are interpolated in the logarithm of thickness. Dose in silicon is the dose in water times the ratio of stopping powers: 0.80 for ions, 0.84 for electrons and positrons, 0.90 for photons and about 0.05 for neutrons, because silicon has no hydrogen.
Each target gets a bar split by particle type, a total for the duration you choose, and a marker on a logarithmic ladder of reference doses.
The reference ladder
| Used for | Source | Basis |
|---|---|---|
| Banana ≈ 0.1 µSv committed dose (K-40) | this project Conventional ballpark used in radiation-protection outreach, not a measurement | rule of thumb |
| Chest X-ray (PA) 0.02 mSv; chest CT 6.1 mSv | Mettler et al. (2008) | review of measurements |
| NY–LA round-trip flight 0.03 mSv | Bardo & Brown (2008) Table 2 | review |
| US natural background 3.1 mSv/yr | NCRP Report No. 160 (2009) | standard |
| Deep-space GCR inside MSL: 1.84 mSv/day | Zeitlin et al. (2013) | primary measurement |
| US occupational limit 50 mSv/yr TEDE | 10 CFR 20.1201 | regulation |
| NASA career limit 600 mSv effective dose | NASA-STD-3001 Vol. 1 Rev. B (2022) Vol. 1 Rev. B (2022) | standard |
| ARS above ~0.7 Gy acute; LD50/60 ~2.5–5 Gy without treatment | CDC, Acute Radiation Syndrome: Information for Clinicians | guidance |
| Total-ionizing-dose hardness levels M 3 krad(Si) … H 1 Mrad(Si) | MIL-PRF-38535 RHA designators | standard |
| Si/water dose ratios (0.80 ions, 0.84 e±, 0.90 γ, ~0.05 n) | this project Bethe stopping-power ratio (Z/A and I = 75 vs 173 eV); photon μ_en/ρ ratio near 1 MeV; Si neutron kerma vs tissue (order of magnitude) | derived |
How well it does
- Behind 10 g/cm² at 1 AU, a chip receives 29.6 mrad(Si)/day in the model. The silicon detector of the Radiation Assessment Detector measured 33.2 on the way to Mars Zeitlin et al. (2013).
- The crew value there, 1.1 mSv/day, is below the 1.84 mSv/day measured, because ours includes 5 g/cm² of body in front of the organ.
- On an orbit like the Space Station's, crew inside 10 g/cm² come out near 0.85 mSv/day, about twice the 0.2 to 0.5 mSv/day reported for the Station. The trapped-proton model is the weak point; see the radiation belts.
- The model's mean quality factor on the Station is lower than measured Berger et al. (2016), because a point dose leaves out the fragments that protons make inside the body itself.
Treat every dose here as good to a factor 2 to 3. The full comparisons are on the validation page.
Why the quiet-time dose is higher far from the Sun
The Sun's steady output is sunlight and the 1 keV solar wind. A suit or a hull stops both in its first micrometers, so neither adds to the dose inside. In quiet times that dose comes from galactic cosmic rays, which arrive from outside and are partly held back by the solar wind. Their intensity therefore grows slowly outward: in this model a spacewalk is about 1.5 mSv/day between 0.1 and 1 AU and about 2.2 mSv/day at 15 AU.
The inverse-square intuition is right for solar storms. Inside 1 AU the peak rate of a solar particle event scales as r⁻²·⁷, so at 0.11 AU the peak of the October 2003 event is about 400 times its value at Earth. The dose panel says which regime you are in.
Dose against depth in the Python engine
- Method
- SHIELDOSE-2 for electrons, bremsstrahlung and protons.
- Checked against
- Nothing independent yet.
- Expect
- No heavy ions or neutrons, so deep-shielding cosmic-ray dose is underestimated.
The Python engine also offers SHIELDOSE-2 Seltzer (1994), the long-standing tool for dose behind aluminum from trapped particles and solar protons. It gives dose against depth for a slab and a solid sphere.