radiation.space
Wiki contents

Dose

From particle spectra to what a person or a chip absorbs, and how the "dose here" panel puts that next to doses you already know.

Three quantities

How we compute dose

Method
Charged-particle fluence times stopping power, with the ICRP 60 quality factor; neutrons and photons as the mean dose in a water sphere of 15 cm radius.
Checked against
MSL/RAD in cruise and the DOSIS dosimeters on the ISS.
Expect
A factor 2 to 3. The mean quality factor is low because target fragments made inside the body are left out.

Starting from the spectra inside a wall (see shielding):

The charged and neutral parts therefore answer slightly different questions, a point and a body-sized sphere. Both are reported.

The "dose here" panel

Click empty space in the 3D explorer and the panel shows four targets.

TargetWhat it stands for
Astronaut on a spacewalkDose equivalent at 5 g/cm² depth, the depth of blood-forming organs, behind a 0.3 g/cm² suit
Astronaut insideThe same, behind the wall you choose: 1, 3, 10 or 30 g/cm²
Silicon chip, exposedAbsorbed dose in silicon behind a 0.3 g/cm² lid
Silicon chip insideAbsorbed dose in silicon behind the chosen wall

Thicknesses between the five simulated ones are interpolated in the logarithm of thickness. Dose in silicon is the dose in water times the ratio of stopping powers: 0.80 for ions, 0.84 for electrons and positrons, 0.90 for photons and about 0.05 for neutrons, because silicon has no hydrogen.

Each target gets a bar split by particle type, a total for the duration you choose, and a marker on a logarithmic ladder of reference doses.

The reference ladder

Used forSourceBasis
Banana ≈ 0.1 µSv committed dose (K-40)this project
Conventional ballpark used in radiation-protection outreach, not a measurement
rule of thumb
Chest X-ray (PA) 0.02 mSv; chest CT 6.1 mSvMettler et al. (2008)review of measurements
NY–LA round-trip flight 0.03 mSvBardo & Brown (2008)
Table 2
review
US natural background 3.1 mSv/yrNCRP Report No. 160 (2009)standard
Deep-space GCR inside MSL: 1.84 mSv/dayZeitlin et al. (2013)primary measurement
US occupational limit 50 mSv/yr TEDE10 CFR 20.1201regulation
NASA career limit 600 mSv effective doseNASA-STD-3001 Vol. 1 Rev. B (2022)
Vol. 1 Rev. B (2022)
standard
ARS above ~0.7 Gy acute; LD50/60 ~2.5–5 Gy without treatmentCDC, Acute Radiation Syndrome: Information for Cliniciansguidance
Total-ionizing-dose hardness levels M 3 krad(Si) … H 1 Mrad(Si)MIL-PRF-38535
RHA designators
standard
Si/water dose ratios (0.80 ions, 0.84 e±, 0.90 γ, ~0.05 n)this project
Bethe stopping-power ratio (Z/A and I = 75 vs 173 eV); photon μ_en/ρ ratio near 1 MeV; Si neutron kerma vs tissue (order of magnitude)
derived

How well it does

Treat every dose here as good to a factor 2 to 3. The full comparisons are on the validation page.

Why the quiet-time dose is higher far from the Sun

The Sun's steady output is sunlight and the 1 keV solar wind. A suit or a hull stops both in its first micrometers, so neither adds to the dose inside. In quiet times that dose comes from galactic cosmic rays, which arrive from outside and are partly held back by the solar wind. Their intensity therefore grows slowly outward: in this model a spacewalk is about 1.5 mSv/day between 0.1 and 1 AU and about 2.2 mSv/day at 15 AU.

The inverse-square intuition is right for solar storms. Inside 1 AU the peak rate of a solar particle event scales as r⁻²·⁷, so at 0.11 AU the peak of the October 2003 event is about 400 times its value at Earth. The dose panel says which regime you are in.

Dose against depth in the Python engine

Method
SHIELDOSE-2 for electrons, bremsstrahlung and protons.
Checked against
Nothing independent yet.
Expect
No heavy ions or neutrons, so deep-shielding cosmic-ray dose is underestimated.

The Python engine also offers SHIELDOSE-2 Seltzer (1994), the long-standing tool for dose behind aluminum from trapped particles and solar protons. It gives dose against depth for a slab and a solid sphere.

Page status: draft, updated 2026-11-15. radiation.space 0.1.0 (3bb1861af578).
These are estimates for learning and early trade studies. They are not a substitute for a mission radiation analysis, and nothing here is medical advice.