radiation.space
Wiki contents

Shielding

What the environment becomes behind a spacecraft wall. A wall removes some particles, slows others, and makes new ones.

What a wall does

Shielding is not a filter. A wall stops low-energy particles outright and slows the rest. But an energetic proton or nucleus that hits a nucleus in the wall breaks it up, and the fragments come out the far side: neutrons, gamma rays, pions, lighter nuclei. Electrons radiate X-rays as they stop.

So behind a wall there are fewer of some particles and more of others. For solar particle events, which are soft, a wall helps a great deal. For galactic cosmic rays, which are hard, the first few g/cm² barely change the dose, and the neutrons made in a thick wall can make matters worse.

Thickness is given as areal density, in g/cm²: what matters is how much material a particle crosses, not how many millimeters. One g/cm² of aluminum is 3.7 mm.

How we model it

Method
Geant4 11.4.1 with the QBBC physics list: a spherical aluminum shell under isotropic irradiation, 0.3 to 30 g/cm².
Checked against
The MSL/RAD cruise dose, and SHIELDOSE-2 for protons.
Expect
See the validation results.

We ran Geant4 Agostinelli et al. (2003) Allison et al. (2006) Allison et al. (2016) once, ahead of time, and saved the answer as response matrices. Folding a spectrum through a matrix takes a few milliseconds in a browser.

Each outside species is folded through its matrix. Nuclei without a matrix of their own use the nearest heavier simulated nucleus, with the charges of the fragments shifted to match.

Inside means the interior average. A point off center sees parts of the wall at a slant, so its particles crossed more material. For thin walls and soft spectra the average over the interior is 0.6 to 0.8 of the value at the exact center. For penetrating radiation it is close to 1.

Assumptions and limits

A cross-check

At the distance of Mars, in quiet times at φ = 480 MV, behind 10 g/cm² of aluminum:

MethodDose in water
Matrix fold: charged point dose plus the neutral dose in a sphere0.47 mGy/day
Direct Geant4 run, mean over a water sphere of 10 cm radius0.38 ± 0.02 mGy/day
Direct Geant4 run, sphere of 2 cm radius (few events)0.58 ± 0.22 mGy/day

A body-sized sphere shields its own interior, so its mean dose sits below the point dose, as it should.

Sources

Used forSourceBasis
Transport: Geant4 11.4.1, QBBC reference physics list, 0.1 mm production cutAgostinelli et al. (2003); Allison et al. (2006); Allison et al. (2016)code
Python bindingsgeant4_pybind 0.1.3
geant4_pybind 0.1.3
code
Data sets: EMLOW 8.8, PARTICLEXS 4.2, PhotonEvaporation 6.1.3, RadioactiveDecay 6.1.4, ENSDFSTATE 3.0, SAIDDATA 2.0, ABLA 3.3, INCL 1.3Geant4 11.4 data sets
Geant4 collaboration (via conda-forge packages)
data
Ion stopping: proton S (Geant4) × Barkas effective charge Z[1 − exp(−125βZ^−2/3)]²Barkas (1963)standard
Electron collision stopping power, density-effect parametersICRU Report 37 (1984); Sternheimer et al. (1984)standard
Quality factor Q(L)ICRP Publication 60 (1991)standard
Validation: GCR dose in transit to Mars (Si 0.332 ± 0.023, plastic 0.461 ± 0.092 mGy/day; 1.84 ± 0.33 mSv/day)Zeitlin et al. (2013); Guo et al. (2015)primary measurement
Validation: absorbed dose in the Columbus module of the ISS, 195 to 360 µGy/day across 11 locations, and a mean quality factor of 3.3 ± 0.1Berger et al. (2016)
DOSIS passive dosimeters
primary measurement
Page status: draft, updated 2026-11-15. radiation.space 0.1.0 (3bb1861af578).
These are estimates for learning and early trade studies. They are not a substitute for a mission radiation analysis, and nothing here is medical advice.